Manufacturer
AirCom Pneumatic
Part number
PVM38-56
Country
Germany
Sale of any product from the AirCom Pneumatic catalog at competitive prices
2technologie will help you choose and buy products and spare parts from AirCom Pneumatic (official website: www.aircom.net). We sell only certified goods and give an official guarantee from the manufacturer AirCom Pneumatic
Mass flow meter directly measuring flow according to constant temperature anemometer principle.
Features: Low pressure drop and immunity against dirt and humidity. Measurement unaffected by pressure and temperature changes. No moving parts, installation in virtually any position.
Principle: Two stainless steel probes - a heater and temperature probe - protrude inside the bore. A constant difference in temperature is created. The energy required is proportional to flow.
Media: compressed air, air as well as virtually all gases and gas mixtures
Compensation: Neither temperature nor pressure have to be compensated. There are no moving parts within the flow meter, therefore it is virtually wear-free.
Pressure drop: Low pressure drop because solely two stainless steel probes protrude inside the smooth, round measurement cell. The use of screw connections with a nominal size as big as possible is suggested.
Temperature_range: 0 °C to 50 °C / 32 °F to 122 °F
Operating_pressure: max. 10 bar
Differential_pressure: device dependent
Body: aluminium, optionally SST 316L
Elastomer: Viton®, optionally EPDM or Kalrez®
Sensor: stainless steel 316L
strainer: stainless steel
Features: Low pressure drop and immunity against dirt and humidity. Measurement unaffected by pressure and temperature changes. No moving parts, installation in virtually any position.
Principle: Two stainless steel probes - a heater and temperature probe - protrude inside the bore. A constant difference in temperature is created. The energy required is proportional to flow.
Media: compressed air, air as well as virtually all gases and gas mixtures
Compensation: Neither temperature nor pressure have to be compensated. There are no moving parts within the flow meter, therefore it is virtually wear-free.
Pressure drop: Low pressure drop because solely two stainless steel probes protrude inside the smooth, round measurement cell. The use of screw connections with a nominal size as big as possible is suggested.
Temperature_range: 0 °C to 50 °C / 32 °F to 122 °F
Operating_pressure: max. 10 bar
Differential_pressure: device dependent
Body: aluminium, optionally SST 316L
Elastomer: Viton®, optionally EPDM or Kalrez®
Sensor: stainless steel 316L
strainer: stainless steel